Efficacy and Safety of Zotarolimus-eluting Stent Overexpansion With OCT (ONYSOVER)
In vivO Study of assessmeNt for Efficacy and safetY of Zotarolimus-eluting Stent OVERexpansion With Optical Coherence Tomography (ONYSOVER Trial)
Sponsor: Medtronic
A observational or N/A phase clinical study on Coronary Artery Disease and Optical Coherence Tomography, this trial is ongoing. The trial is conducted by Medtronic and has accumulated 8 data snapshots since 2022. Cardiovascular trials of this type often inform treatment guidelines for long-term patient management.
Study Description(click to expand)Single stent implantation (also called "provisional stenting") is currently the preferred technique for percutaneous coronary interventions on the majority of unprotected left main (LM) or non-LM bifurcations. During provisional stenting, proximal optimization technique (POT), proved to correct both the proximal main vessel (MV) malapposition and/or optimize the side branch (SB) ostium strut opening for proper wire re-crossing into the distal cell, might be crucial step and may warrant improved long-term clinical outcomes in the setting of major proximal and distal reference vessel size mismatch (like often in LM bifurcation or diffuse tapered long lesion). Recently, second-generation drug-eluting stent (DES) implantation is recommended over BMS for PCI in patients with ischemic heart disease (IHD) due to superior efficacy and safety. However, percutaneous coronary intervention (PCI) with DES for lesion with the discrepancy of proximal and distal reference vessel size, such as LM or non-LM bifurcation lesion, diffuse tapered long lesion, and ectatic or aneurysmal coronary artery, is challenging due to stent optimization because expert consensus recommend that stent diameter is selected by distal reference diameter, which need stent overexpansion for POT. OCT is a utility that can accurately measure reference vessel diameter and lesion length pre-PCI, which is useful for stent...
Single stent implantation (also called "provisional stenting") is currently the preferred technique for percutaneous coronary interventions on the majority of unprotected left main (LM) or non-LM bifurcations. During provisional stenting, proximal optimization technique (POT), proved to correct both the proximal main vessel (MV) malapposition and/or optimize the side branch (SB) ostium strut opening for proper wire re-crossing into the distal cell, might be crucial step and may warrant improved long-term clinical outcomes in the setting of major proximal and distal reference vessel size mismatch (like often in LM bifurcation or diffuse tapered long lesion).
Recently, second-generation drug-eluting stent (DES) implantation is recommended over BMS for PCI in patients with ischemic heart disease (IHD) due to superior efficacy and safety. However, percutaneous coronary intervention (PCI) with DES for lesion with the discrepancy of proximal and distal reference vessel size, such as LM or non-LM bifurcation lesion, diffuse tapered long lesion, and ectatic or aneurysmal coronary artery, is challenging due to stent optimization because expert consensus recommend that stent diameter is selected by distal reference diameter, which need stent overexpansion for POT.
OCT is a utility that can accurately measure reference vessel diameter and lesion length pre-PCI, which is useful for stent optimization by a suitable stent selection and pre- and post-interventional strategies. OCT also demonstrated higher sensitivity to detect stent malapposition, edge dissection, and tissue prolapsed than IVUS post-PCI. Thus, OCT-guided PCI can be helpful to optimize DES implantation in patients with dilated coronary arteries despite the potential limitation of depth penetration and attenuation images by thrombus.
Zotarolimus-eluting stent (Onyx family stent, Medtronic, Santa Rosa, CA, USA) was developed in response to the demand for stents with improved radiographic visibility. It has a novel thin strut composite wire stent platform that is covered with the same zotarolimus-eluting durable polymer coating as its predecessors. The metallic stent platform consists of a composite wire made from a dense platinum-iridium core, which makes the struts radiopaque, and an outer layer of cobalt-chromium alloy. The dense core also allows for reduced strut thickness, which might be associated with a decreased risk of stent thrombosis.
Onyx family stent has been labeled for maximum stent inner diameter by easy crowns platform (2.00-2.5 mm, 6.5 Crowns; 2.75-3.0 mm, 8.5 crowns; 3.5-4.0 mm, 9.5 crowns; 4.5-5.0 mm; 10.5 crowns). However, safety and efficacy of DES overexpansion is still concerned as safety of efficacy of there are limited data regarding Onyx family stent overexpansion in vivo.
This study aims to evaluate the safety and efficacy of Onyx family stent overexpansion for lesion with the discrepancy between proximal and distal reference vessel which need stent overexpansion for POT, assessed by OCT, providing high-resolution (10 µm) imaging which enables the detection of strut fracture, malapposition.
Status Flow
Change History
8 versions recorded-
Apr 28, 2026 — Present [daily]
Active Not Recruiting
Status: Recruiting → Active Not Recruiting
-
Dec 2025 — Apr 2026 [monthly]
Recruiting
-
Sep 2025 — Dec 2025 [monthly]
Recruiting
-
Sep 2024 — Sep 2025 [monthly]
Recruiting
-
Jul 2024 — Sep 2024 [monthly]
Recruiting
Status: Unknown Status → Recruiting
▶ Show 3 earlier versions
-
May 2024 — Jul 2024 [monthly]
Unknown Status
Status: Recruiting → Unknown Status
-
Nov 2022 — May 2024 [monthly]
Recruiting
-
May 2022 — Nov 2022 [monthly]
Recruiting
First recorded
Mar 2022
Trial started
Per CT.gov start date — pre-dates our first snapshot
Eligibility Summary
Investigators aimed to evaluate efficacy and safety of expansion capacity of zotarolimus-eluting Stent assessed by optical coherence tomography (OCT) in vivo study.
Contact Information
- Medtronic
- Severance Hospital
- Yonsei University