Comparison of Flex-It Stylet to Malleable Stylet for GlideScope Intubation: A Randomized Controlled Trial
Sponsor: London Health Sciences Centre
A NA clinical study on Intubation, this trial is completed. The trial is conducted by London Health Sciences Centre and has accumulated 8 data snapshots since 2008. Longitudinal tracking of this trial contributes to a broader understanding of treatment development timelines.
Study Description(click to expand)Written informed consent will be obtained by one of the study investigators, and a copy will be given to each participant. Written informed consent will also be obtained from the operator of the GlideScope. Envelopes with computer-generated randomized group assignments will be present at each site. The envelopes will be consecutively numbered (i.e. "U1", "U2" for University Hospital, "S1", "S2" for St Joseph's Health Care, etc.). After consent, randomization will occur by selecting the next consecutive envelope. The envelope will contain the data collection form as well as a piece of paper that has the following information: * at the top will be the randomization group (A, B) and a text description of the endotracheal tube angle and stylet (i.e. "90 degrees - malleable stylet") * in the body of the piece of paper will be a template that shows the exact shape into which the tube must be bent, including where the distal and proximal ends are, the angle of curvature that must be followed, and the location along the length of the tube at which to create this angle. The angle and location will be the same for both males and females. There are three distinct anesthesia providers...
Written informed consent will be obtained by one of the study investigators, and a copy will be given to each participant. Written informed consent will also be obtained from the operator of the GlideScope. Envelopes with computer-generated randomized group assignments will be present at each site. The envelopes will be consecutively numbered (i.e. "U1", "U2" for University Hospital, "S1", "S2" for St Joseph's Health Care, etc.). After consent, randomization will occur by selecting the next consecutive envelope. The envelope will contain the data collection form as well as a piece of paper that has the following information:
* at the top will be the randomization group (A, B) and a text description of the endotracheal tube angle and stylet (i.e. "90 degrees - malleable stylet") * in the body of the piece of paper will be a template that shows the exact shape into which the tube must be bent, including where the distal and proximal ends are, the angle of curvature that must be followed, and the location along the length of the tube at which to create this angle. The angle and location will be the same for both males and females.
There are three distinct anesthesia providers involved in the conduct of this study, as follows:
1. "operator" - person performing the intubation 2. "timer" - person timing the outcome (one of the co-investigators) 3. "shaper" - person who ensures that the angle and stylet of the tube matches the group to which the patient was allocated
Because the person intubating must be blind up until the time at which the tube is to be used, the unopened envelope will be taken to a third anesthesia provider, who will prepare the ETT with stylet in an area that is not visible to the person performing the intubation or to the person timing the intubation. The person performing the intubation will specify what size of tube to be prepared. This will most commonly be 7.5 mm internal diameter (ID) for a female and 8.0 ID for males, but the operator is free to use whatever size they feel is appropriate. The tube size selection will take place before unblinding so the group allocation cannot affect the decision of tube size.
The tubes will all be cut at the 27 cm marking. "Group A" ETT's will be shaped with the aid of a standard malleable stylet (Rusch 14 Fr) that has been lubricated with single-use water-soluble lubricant. "Group B" ETT's will be instrumented with the Flex-It Stylet, with identical lubricant. The prepared tube will then be concealed under a standard green OR towel and brought to the operating room (OR). This tube will be placed close to the patient's head so that it is readily accessible.
Data Collection
In the OR, the GlideScope will be turned on at least 60 seconds before use so that the lens can warm-up to prevent fogging. The patient will be cared for in the usual fashion with respect to monitoring and induction of general anesthesia. To ensure adequate pre-oxygenation, the patient's end-tidal oxygen must be ≥ 70%. Muscle relaxation will be used, and the agent used is at the discretion of the operator. After induction of anesthesia, bag-mask ventilation will be used in the usual fashion until the operator decides to proceed to laryngoscopy with the GlideScope. The operator will remain blinded to the group allocation until after the laryngoscopic view has been obtained with the GlideScope, where upon he will be handed the endotracheal tube.
The timer (who cannot see the tube under the green towel) will watch the operator until the GlideScope is inserted into the patient's mouth, start the timer, and then turn 180º to face the anesthetic monitor. The timer will not be able to see the ETT, stylet, or curvature because he will be facing the monitor screen.
Timing will continue until end-tidal CO2 of at least 30 mmHg is seen on the anesthesia monitor, at which point the data collection form will be filled out, and the study protocol will be finished. (The time to intubation will be recorded to the nearest tenth of a second.) If the operator fails to intubate within 3 attempts or 150 seconds, the intubation will be noted as a failure, and the ultimately successful means of securing the airway will be recorded.
The definition of an "attempt" for the purposes of this clinical trial are as follows:
1. anytime the GlideScope blade is removed from the patients mouth and then re-inserted 2. anytime the endotracheal tube is re-shaped (regardless of whether or not the GlideScope is actually removed from the patient's mouth 3. if substantial adjustments are made to the patient's position (such as head position, neck flexion, or neck extension). Small movements that would occur in the normal process of intubation would not count as "substantial".
If oxygen desaturation (as recorded by pulse oximetry) below 95% occurs, then the patient will be ventilated in the usual fashion to ensure oxygenation, and re-attempting intubation using the GlideScope may proceed, but the timing will continue, and the same limits to successful intubation (within 3 attempts or total of 150s) will apply. Between attempts, the tube may be re-shaped by the operator if the operator feels that another curvature would be preferred.
Status Flow
Change History
8 versions recorded-
Apr 2025 — Present [monthly]
Completed NA
-
Jan 2025 — Apr 2025 [monthly]
Completed NA
-
Sep 2024 — Jan 2025 [monthly]
Completed NA
-
Jul 2024 — Sep 2024 [monthly]
Completed NA
-
Oct 2021 — Jul 2024 [monthly]
Completed NA
▶ Show 3 earlier versions
-
Jan 2021 — Oct 2021 [monthly]
Completed NA
-
Jun 2018 — Jan 2021 [monthly]
Completed NA
-
Jan 2017 — Jun 2018 [monthly]
Completed NA
First recorded
Jan 2008
Trial started
Per CT.gov start date — pre-dates our first snapshot
Eligibility Summary
No eligibility information available.
Contact Information
- London Health Sciences Centre
- London Health Sciences Centre Research Institute OR Lawson Research Institute of St. Joseph's
- Unity Health Toronto
For direct contact, visit the study record on ClinicalTrials.gov .